Klemm, Mathias; Kellnar, Antonia; Naumann, Dominik; Brunner, Stefan; Stremmel, Christopher
ORCID: 0000-0002-6404-1421; Ahmad, Irfan
(2025):
Diagnostic Power of Head‐Up Tilt Test Enhanced by Autonomic ECG Parameters and Beat‐to‐Beat Hemodynamic Monitoring.
Cardiology Research and Practice, 2025: 5239630.
ISSN 2090-8016
Veröffentlichte Publikation
Cardiology_Research_and_Practice_-_2025_-_Klemm_-_Diagnostic_Power_of_Head‐Up_Tilt_Test_Enhanced_by_Autonomic_ECG.pdf
Abstract
Objectives: The head-up tilt test (HUTT) is a well-established diagnostic procedure used to differentiate between the types of syncope. Since its introduction in 1986, the protocol has undergone several refinements aimed at increasing diagnostic accuracy. Despite growing interest in advanced autonomic ECG parameters and beat-to-beat blood pressure monitoring, their integration into routine HUTT protocols remains limited.
Methods: In this study, we compared the conventional HUTT protocol using two-minute interval monitoring with an advanced protocol incorporating autonomic ECG parameters—periodic repolarization dynamics (PRD) and deceleration capacity (DC)—as well as continuous beat-to-beat hemodynamic monitoring.
Results: The extended protocol improves diagnostic resolution by detecting more pronounced hemodynamic fluctuations, enabling real-time trend analysis, and allowing earlier recognition of impending syncope. The tilt phase was characterized by a significant initial increase in PRD, and patients with syncope showed significantly higher PRD values during the tilt phase (8.14 vs. 3.91 deg2, p = 0.043).
Conclusions: Continuous hemodynamic monitoring during HUTT improves the diagnostic quality by detecting changes at an early stage, thus allowing to anticipate syncope and to clearly identify its etiology. While beat-to-beat blood pressure monitoring is already recommended by current syncope guidelines, we propose the additional evaluation of autonomic ECG parameters as a valuable extension to standard protocols.
| Dokumententyp: | Artikel (Klinikum der LMU) |
|---|---|
| Organisationseinheit (Fakultäten): | 07 Medizin > Klinikum der LMU München > Medizinische Klinik und Poliklinik I (Kardiologie) |
| DFG-Fachsystematik der Wissenschaftsbereiche: | Lebenswissenschaften |
| Veröffentlichungsdatum: | 23. Okt 2025 07:09 |
| Letzte Änderung: | 23. Okt 2025 07:09 |
| URI: | https://oa-fund.ub.uni-muenchen.de/id/eprint/2174 |
| DFG: | Gefördert durch die Deutsche Forschungsgemeinschaft (DFG) - 491502892 |
![Publikation bearbeiten['Plugin/Screen:render_action_img_suffix' not defined] Publikation bearbeiten](/style/images/action_view.png)