Killing, Christoph; Wekerle, Maximilian; Sutherland, Jayne S.; Rassool, Mohammad; Zurba, Lindsay; Ivanova, Olena; Charalambous, Salome; Khosa, Celso; Wallis, Robert S.; Hoelscher, Michael; Calderwood, Claire; Allwood, Brian; Castelletti, Noemi; Rachow, Andrea; Rachow, Andrea; Hoelscher, Michael; Castelletti, Noemi (2026): Deep learning approach for probabilistic pulmonary function estimation from chest X-ray and peak expiratory flow rate. Communications Medicine, 6: 330. ISSN 2730-664X
Veröffentlichte Publikation
s43856-026-01702-7.pdf
Abstract
Background
Spirometry remains the gold standard for assessing pulmonary function. Deep learning models have demonstrated potential for estimating measurements from chest X-rays (CXR). We aim to effectively address anatomical variability and integrate probabilistic reasoning to enhance estimation reliability near diagnostic thresholds.
Methods
We developed a probabilistic machine learning framework to estimate the forced expiratory volume in the first second (FEV1) and the forced vital capacity (FVC) as measured through spirometry. Estimations use morphologically regularized CXRs and anthropometric-normalized peak expiratory flow rate (PEFR) as proxy for volumetric information unavailable in imaging. By estimating FEV1 and FVC z-scores, we decouple appearance from anatomic variability. We demonstrate our method on a multi-national cohort of pulmonary tuberculosis patients exhibiting diverse structural abnormalities and ventilatory impairments.
Results
Using ensembles of neural networks, we analyze 982 CXR and spirometry pairs from 568 individuals. The best model achieves an area under curve (AUC) of 0.879 (FEV1; 99%CI 0.876, 0.881) and 0.853 (FVC; 99%CI 0.850, 0.856) in identifying moderate or severe lung-function impairment on a previously unseen test-set, signifying an AUC improvement of 0.144 (FEV1) and 0.118 (FVC) over previous methods. When allowing up to 10% of samples to remain unclassified due to uncertainty, AUC further rises to 0.894 (0.891, 0.896) and 0.857 (0.854, 0.860), respectively. Our method performs robustly across diverse impairment types and CXR pathologies.
Conclusions
Our study shows that decoupling anatomical variability from functional assessment improves lung function estimation. Incorporation of probabilistic modeling improved diagnostic reliability around a decision threshold. Therefore, our system offers a promising approach to practical lung function estimation in settings where spirometry is unavailable.
| Dokumententyp: | Artikel (Klinikum der LMU) |
|---|---|
| Organisationseinheit (Fakultäten): | 07 Medizin > Klinikum der LMU München > Institut für Infektions- und Tropenmedizin |
| DFG-Fachsystematik der Wissenschaftsbereiche: | Lebenswissenschaften |
| Veröffentlichungsdatum: | 12. Okt 2026 09:32 |
| Letzte Änderung: | 12. Okt 2026 09:32 |
| URI: | https://oa-fund.ub.uni-muenchen.de/id/eprint/2859 |
| DFG: | Gefördert durch die Deutsche Forschungsgemeinschaft (DFG) - 491502892 |
![Publikation bearbeiten['Plugin/Screen:render_action_img_suffix' not defined] Publikation bearbeiten](/style/images/action_view.png)